Project Overview

Microsoft Buildings 121 & 122 Retrofits

Post-Tensioning Solutions completed multiple major retrofits across Microsoft's Redmond campus buildings. For Building 122, we created expansive atrium openings without compromising structural integrity by controlling the de-tensioning and re-anchoring of over 1,200 tendons. This ambitious retrofit provided employees with improved natural light and a more inspiring work environment, all executed without shoring the entire building, and in 6 months.

For Building 121, we performed a complete post-tensioning retrofit of the existing parking structure with tendon replacements and structural upgrades. This included full tendon replacement throughout deteriorated areas, controlled de-tensioning to maintain structural integrity, structural reinforcement of concrete elements, and installation of corrosion protection systems.

Both projects showcase our expertise in complex post-tensioning modifications while maintaining structural integrity and minimizing disruption to occupied buildings.

Project Scope

  • Removed post-tensioned slabs for HVAC penetrations, skylights, and atrium openings; over 1,200 tendons were de-tensioned and re-anchored in six months
  • Full tendon replacement throughout deteriorated areas with controlled de-tensioning to maintain structural integrity
  • Structural reinforcement of concrete elements and installation of corrosion protection systems
  • Complete resealing of post-tensioning anchors
  • Featured on the front of the PTI magazine
  • 2019 NAIOP Washington State Chapter, Redevelopment/Renovation of the Year award winner and People's Choice award winner
  • 2019 Design-Build Institute of America (DBIA) National Award of Merit in the commercial/office category

PT Slab Retrofit

No shoring/ Timeline acceleration

Sectors

Corporate Campus

Special Features

1,200+ Tendons detensioned and re-anchored

Square Feet

275,000

Microsoft Building Overview
Building 122 Retrofit
Atrium Opening Creation
Post-Tensioning Retrofit Process
Completed Structural Repairs
Tendon Installation
Tendon Management
Building 122 Retrofit Process
Completed Atrium
Completed Atrium
Completed Atrium
Completed Atrium
Completed Atrium
Microsoft Building 121 Parking Structure
Heading Icon
Company Porjects

Related Projects

Kirkland Urban

Kirkland Urban

Performed two major slab retrofits, including stairwell openings, skylight installation, and elevator expansion by de-tensioning and relocating tendons.

T-Mobile 4 Newport to 5 Newport Bridge

T-Mobile 4 Newport to 5 Newport Bridge

Post-Tension Modification – De-stressed and re-anchored 20 live tendons for new skybridge installation.

Reliable Solutions. Real Expertise.

Whether you need barrier cable installation, post-tension repairs, or concrete scanning — we bring clarity, safety, and precision to every project. Backed by decades of certified experience, we make it easier to protect your structure and stay on schedule.

Book a job walk
image